Paradigm LightDesigner is installed by running the setup installer on a PC running Windows 7, Windows 10, or Windows 11. Additional hardware requirements include:
It is highly recommended that you review the System Estimator View within LightDesigner for a visual indication of your system in its current state compared to the maximum allowed per processor and per project.
Note: Exceeding any of the maximum capabilities outlined in this document can have negative effects on your system performance.
Object | Limits per Processor | ||||||
---|---|---|---|---|---|---|---|
1.0.0–1.1.1 | 1.1.2–1.2.2 | 2.0.1–2.0.5 | 2.1.0–2.1.2 | 3.0.0 | 3.1.0–4.2 | 5.0.1 and later | |
Network Station Power Supply | 5 | ||||||
Echo Expansion Bridge (EEB)* | 16 | ||||||
Mobile Button Stations | 16 | ||||||
Channel outputs | 1,024 | ||||||
Stations† | 63 | 128 | |||||
Touchscreens‡ | 18 | ||||||
Wireless Access Stations§ | 32 | ||||||
*EEB Spaces, Walls, and Zones count towards overall project maximums. See Note below for more information. †Includes LinkConnect, NetConnect (Ethernet), and Mobile Button. ‡Includes all touchscreen variants, including wall-mount, portable, wireless handheld, and docking stations. Up to six may use LinkConnect with the appropriate auxiliary power supply. §A maximum of 16 are allowed per compatible Paradigm Station Power Supply. |
Note: Use care when configuring your system with Echo Expansion Bridges. Each Echo zone counts against the Paradigm Processor channel count (1,024 channels).
For example, a connected Echo system with 16 spaces, 16 zones, and 4 Echo Expansion Bridges would utilize the entire output capacity of the Paradigm Processor (1,024 channels) leaving no channels to patch additional DMX/sACN addresses.
Reducing the number of Echo spaces and zones an EEB uses will reduce the overall impact on the Paradigm Processor channel count.
Paradigm processors are limited to two hardline DMX connections configured as either inputs or outputs depending on processor and rack type.
Note: In DRd enclosures, Port B is always an output.
Two input sources of a single universe carry the same amount of data as one input source of two universes.
Example: In a system with seven ERn processors, Processors 1-6 are configured so that each is sending DMX A's input to sACN 1, and DMX B's input to sACN 2. If Processor 7 is configured to listen to sACN universes 1 and 2, it is receiving 12 universes of data.
sACN / DMX Universes | Limits |
---|---|
Output by a single processor | 12 |
Input to a single processor | 12 |
Outputs from a channel in a configuration | 6 |
Inputs to a channel in a configuration | 6 |
Paradigm processors can output up to 1,024 unique levels at a time. While many channels consist of a single intensity attribute level, some fixtures consist of multiple parameters that require one level each. The same value calculated in multiple places (such as a single channel patched to multiple addresses) counts as a single level.
Note: A maximum of 1,024 unique addresses can be snapshot at a time.
Stations | Limits per Server Project | |
---|---|---|
2.0.1‑2.0.5 | 2.1.0 and later | |
Central Control Server (P‑CCS) | 1 | |
Sub-projects (*.pcf) per Server Project (*.spcf) | 24 | 64 |
Paradigm Processor (P‑ACP) per Server Project | 48 | 64 |
Virtual Touchscreen (P‑TS18/P‑TSI/P‑VTS) | 24 | 32 |
BACnet I/O Binary Inputs, Binary Outputs, Analog Inputs, and Analog Outputs | 1,024 |
Object | Limits per Project | |||||
---|---|---|---|---|---|---|
1.0.0–1.1.1 | 1.1.2–1.2.2 | 2.0.1–2.0.5 | 2.1.0–2.1.2 | 3.0.0‑5.0.0 | 5.0.1 and later | |
Processors* | 12 | |||||
Controls† | 32,768 | 65,535 | ||||
Indicators† | 32,768 | 65,535 | ||||
Station Pages† | 1,024 | 65,535 | ||||
Spaces* | 128 | 255 | ||||
Timed Events | 4,096 | |||||
Holidays | 1,024 | |||||
Overrides | 1,024 | |||||
Triggers* | 1,024 | |||||
Macros | 1,024 | |||||
Macro Steps | 32,768 | |||||
Presets | 1,024 | |||||
Palettes | 1,024 | |||||
Sequences | 512 | |||||
Stations* | 512 | 744 | 1,536 | |||
UH1RS Connectors* | 256 | 1,536 | ||||
Touchscreens * | 216 | |||||
Virtual Touchscreen Stations | 24 | 32 | ||||
Walls* | 128 | |||||
Mosaic Shows | 8 | |||||
Echo Expansion Bridge (EEB)‡ | 128 | |||||
Control Groups† | 2,048 | 4,096 | ||||
Unique Scripts§ | 256 | |||||
Script Instances (all objects) | 65,535 | |||||
Script Variables | 65,535 | |||||
*Sub-projects observe these limits separately. †Sub-projects and the total collection of server-level items independently observe these limits. ‡EEB Spaces, Walls, and Zones count towards overall project maximums. §Individual totals for Actions, Condition Scripts, Controls, Indicators, and Triggers. |
Note: Adding a Central Control Server to a project does NOT increase the maximum number of allowed Echo Expansion Bridges (EEBs) per Paradigm system.
Stations attached to a Paradigm processor via LinkConnect, including touchscreens, are subject to the limitations identified below.
Stations | Limits per Processor | |
---|---|---|
1.0.0–4.2.4 | 5.0.1 and later | |
Connected per processor | 63 | 128 |
Connected to a Station Power Module (P‑SPM)* | 31 | |
Connected to a Station Power Module Mk2 (P‑SPM‑E)* | 63 | |
Connected to a Repeater (P‑REP)* or Dual Repeater (P‑DREP)* | 31 | |
Connected to a Network Station Power Supply (P‑NSPS‑D)† | 63 | |
*Maximum one P‑SPM‑E/P‑SPM and one P‑REP/P‑DREP per processor. †Maximum five P‑NSPS‑D per processor. |
Note: A Station Power Module or Network Station Power Supply is required for any processor controlling LinkConnect stations.
Note: Portable stations only count against these limits when they are physically connected to the system.
Wired and wireless touchscreen hardware have their own set of limitations to consider when planning your system.
Wired Touchscreen | Limits per Paradigm Processor |
---|---|
Connected via NetConnect* | 18 |
Connected via LinkConnect† | 6 |
Connected to a Station Power Module (P‑SPM) | 4 |
Connected to a Station Power Module Mk2 (P‑SPM‑E) | 4 |
Connected to a Network Station Power Supply (P‑NSPS‑D)‡ | 6 |
Connected to a Repeater (P‑REP) or Dual Repeater (P‑DREP) | 4 |
*No more than 18 touchscreens, regardless of model or connection type, can be connected to a single Paradigm Processor (P‑ACP). †A Paradigm Station Power Module or Network Station Power Supply is required for any Paradigm Processor controlling LinkConnect stations. A Portable Touchscreen counts against the Paradigm Processor limits only when it is connected to the system. ‡When used with the appropriate rated 24 VDC power supply. |
Note: The P‑LCD Touchscreen station is not supported in Paradigm v4.0.0 and later software. Systems that include P‑LCDs will need to remain at their current firmware version or upgrade to P‑TS7 touchscreen hardware.
Wireless Touchscreen and Accessory Connections | Limits per Paradigm Processor |
---|---|
Touchscreen to Docking Station (NetConnect) | 18 |
Touchscreen to Wireless Access Station (LinkConnect) | 6 |
Wireless Access Station to Paradigm System (LinkConnect) | 16 |
Touchscreen configurations (.lcdconf) created using ControlDesigner software are for wired, wireless, and Virtual Touchscreen Stations and also have specific software limitations.
Object | Limits per Project | |
---|---|---|
1.0.0–2.0.2 | 2.0.3 and later | |
Popups | 1,024 | |
Pages | 1,024 | |
Action Lists from Buttons and Keypads | 1,024 | 16,384 |
Timed Event Exceptions* | 65,535 | |
*Limited to 365 old (expired) instances per Timed Event. |